Function
|
HT-450J
|
HT-550J
|
HT-450K/KC
|
HT-550K/KC
|
Acquisition meters
|
Input method
|
Touch, key
|
Touch, key
|
Touch, key
|
Touch, key
|
Input
|
Chinese, English
|
Chinese, English
|
Chinese, English
|
Chinese, English
|
Data processing
|
Automated data calculations and result estimation according to specifications
|
Automated data calculations and result estimation according to specifications
|
Automated data calculations and result estimation according to specifications
|
Automated data calculations and result estimation according to specifications
|
Display
|
2.8-inch touch LCD screen
(400×240 pixels)
|
2.8-inch touch LCD screen
(400×240 pixels)
|
2.8-inch touch LCD screen
(400×240 pixels)
|
2.8-inch touch LCD screen
(400×240 pixels)
|
System capacity
|
1000 components, the maximum number of measurement areas of the components is 100
|
1000 components, the maximum number of measurement areas of the components is 100
|
1000 components, the maximum number of measurement areas of the components is 100
|
1000 components, the maximum number of measurement areas of the components is 100
|
Power supply mode
|
Rechargeable, built-in 3200mAh high-capacity imported lithium battery
|
Rechargeable, built-in 3200mAh high-capacity imported lithium battery
|
Rechargeable, built-in 3200mAh high-capacity imported lithium battery
|
Rechargeable, built-in 3200mAh high-capacity imported lithium battery
|
Automatic shutdown
|
The maximum can be set for 120 minutes
|
The maximum can be set for 120 minutes
|
The maximum can be set for 120 minutes
|
The maximum can be set for 120 minutes
|
GPS positioning
|
Yes
|
Yes
|
-
|
-
|
Mechanical rebound meter
|
Nominal kinetic energy
|
4.5J
|
5.5J
|
4.5J
|
5.5J
|
Sensor life
|
More than 200,000 times
|
More than 200,000 times
|
More than 200,000 times
|
More than 200,000 times
|
Strength measurement range
|
50~100MPa
|
50~90MPa
|
50~100MPa
|
50~90MPa
|
Striking spring rate
|
900±40N/m
|
1100±50N/m
|
900±40N/m
|
1100±50N/m
|
Pointer friction
|
0.65±0.15N
|
0.65±0.15N
|
Snap the spring to stretch the length
|
100±0.5mm
|
100±0.5mm
|
100±0.5mm
|
100±0.5mm
|
Strike spring working length
|
106±0.5mm
|
86±0.5mm
|
106±0.5mm
|
86±0.5mm
|
Spherical radius at the end of the striking rod
|
35±1mm
|
18±1mm
|
35±1mm
|
18±1mm
|
Value consistency error
|
≤±1 (Difference between the pointer reading of the mechanical rebound meter and the reading of the instrument screen)
|
≤±1 (Difference between the pointer reading of the mechanical rebound meter and the reading of the instrument screen)
|
≤±1 (Difference between the pointer reading of the mechanical rebound meter and the reading of the instrument screen)
|
≤±1 (Difference between the pointer reading of the mechanical rebound meter and the reading of the instrument screen)
|
The steel anvil rate determines the rebound value
|
88±2
|
83±2
|
88±2
|
83±2
|
Industry and some local regulations to measure strength and test the compressive strength range
|
Industry standard: 20~110MPa
Chongqing standard: 50~80MPa
|
Industry standard: 60~80MPa
Fujian standard: 60~90MPa
|
Industry standard: 20~110MPa
Chongqing standard: 50~80MPa
|
Industry standard: 60~80MPa
Fujian standard: 60~90MPa
|